show ipv6 address

View IPv6 address entries.

Syntax

Command Parameters

{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}

Identifies the slot and port in one of the following formats:

  • a single slot and port (slot/port)

  • a range of slots and ports (slot/port-slot/port)

  • a series of slots and ports (slot/port,slot/port,slot/port)

  • all ports on the same slot (slot/all)

  • all ports on the switch (all)

If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.

<1-4059>

Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1.

tunnel <1-2000>
Displays the address entries specific to a tunnel ID.
vrf WORD<1-16>
Specifies a VRF name. The VRF parameter is optional.
vrfids WORD<0-512>
Specifies a VRF by ID. The VRF parameter is optional.
WORD<0-46>
Specifies an IPv6 address.

Default

None

Command Mode

User EXEC